seca mBCA 514
Product Number 514 1321 139Medical Body Composition Analyzer for determining body composition while standingFurther details
$ Plus delivery costsProduct Properties
- Unique accuracy through whole body MRI validation (skeletal muscle mass) and 4C model (fat mass)
- Handrail with fixed handle positions: Measurements are reproducible and reliable
- Validation studies are bundled and published in the European Journal of Clinical Nutrition 2013/2017, among others
- Comprehensive, personalized normal ranges based on over 3,000 multiethnic subjects
- Possible to evaluate the measurement directly on the monitor
- Extra-large platform: Enough space even for extremely tall people or people affected by severe obesity
- Measuring time is only 17 seconds
Body composition analysis for medical use
As the only BIA solution, the seca mBCA 514 is validated against whole-body MRIs (skeletal muscle mass) and 4C model (fat mass) and its high accuracy has been proven in peer-reviewed studies. Measurement results are clearly prepared and provide an immediate overview of the distribution of muscles, fat and water in the body. The fixed hand-held electrodes enable reproducible and precise measurements in daily practice and clinical operation.
Technical Data
- Accuracy of the first calibration: ± 100 g < 35 kg > ± 0.3%
- Capacity: 300 kg / 660 lbs
- Graduation: 50 g < 150 kg > 100 g / 0.1 lb < 330 lbs > 0.2 lb
- Power supply: Power adapter
- Turn-off time with power supply: No switch off
- Turn-on time with activated HOLD: No switch off
- Interfaces: Ethernet / USB 2.0
- Display: 8.4" Touch-screen display, can be rotated 360°
- Net weight: 79.4 lbs / 36.0 kg
- Product width: 38.4 inch / 976 mm
- Product height: 49.3 inch / 1,251 mm
- Product depth: 32.6 inch / 828 mm
- Platform width: 30.7 inch / 780 mm
- Platform height: 0.5 inch / 12 mm
- Platform depth: 20.1 inch / 510 mm
- BIA measuring method: 8-point Bioelectrical Impedance Analysis
- BIA measurement segments: Right arm, left arm, right leg, left leg, right half of body, left half of body, torso
- BIA measuring period: 17 seconds
- BIA measuring frequency: 1; 1.5; 2; 3; 5; 7.5; 10; 15; 20; 30; 50; 75; 100; 150; 200; 300; 500; 750; 1,000 kHz
- BIA measuring electricity: 100 µA
Functions and Properties
- TARE
- Pre-TARE
- HOLD
- Auto-HOLD
- RESET
- Step-off
- Weighing range switch-over
- lbs/kg switch-over
- lbs/kg/sts switch-over
- cm/inch switch-over
- Calibration / automatic calibration
- BMI
- User-defined zero setting
- SEND/Auto-SEND
- Ethernet
- 8 point measurement
- Segmental measurement
- Multi-frequent measurement
- Patient data input
- Acoustic signals can be activated
- Wireless
- Backlighting
- Date and time at printout
Scope of Delivery
- One licence of seca analytics 115
- Measuring tape seca 201
- Power adapter