Seca

seca mBCA 514

seca mBCA 514

seca mBCA 514

Product Number 514 1321 139Medical Body Composition Analyzer for determining body composition while standing
Further details$ Plus delivery costs

Product Properties

    • Unique accuracy through whole body MRI validation (skeletal muscle mass) and 4C model (fat mass)
    • Handrail with fixed handle positions: Measurements are reproducible and reliable
    • Validation studies are bundled and published in the European Journal of Clinical Nutrition 2013/2017, among others
    • Comprehensive, personalized normal ranges based on over 3,000 multiethnic subjects
    • Possible to evaluate the measurement directly on the monitor
    • Extra-large platform: Enough space even for extremely tall people or people affected by severe obesity
    • Measuring time is only 17 seconds

Body composition analysis for medical use

As the only BIA solution, the seca mBCA 514 is validated against whole-body MRIs (skeletal muscle mass) and 4C model (fat mass) and its high accuracy has been proven in peer-reviewed studies. Measurement results are clearly prepared and provide an immediate overview of the distribution of muscles, fat and water in the body. The fixed hand-held electrodes enable reproducible and precise measurements in daily practice and clinical operation.

Technical Data

  • Accuracy of the first calibration: ± 100 g < 35 kg > ± 0.3%
  • Capacity: 300 kg / 660 lbs
  • Graduation: 50 g < 150 kg > 100 g / 0.1 lb < 330 lbs > 0.2 lb
  • Power supply: Power adapter
  • Turn-off time with power supply: No switch off
  • Turn-on time with activated HOLD: No switch off
  • Interfaces: Ethernet / USB 2.0
  • Display: 8.4" Touch-screen display, can be rotated 360°
  • Net weight: 79.4 lbs / 36.0 kg
  • Product width: 38.4 inch / 976 mm
  • Product height: 49.3 inch / 1,251 mm
  • Product depth: 32.6 inch / 828 mm
  • Platform width: 30.7 inch / 780 mm
  • Platform height: 0.5 inch / 12 mm
  • Platform depth: 20.1 inch / 510 mm
  • BIA measuring method: 8-point Bioelectrical Impedance Analysis
  • BIA measurement segments: Right arm, left arm, right leg, left leg, right half of body, left half of body, torso
  • BIA measuring period: 17 seconds
  • BIA measuring frequency: 1; 1.5; 2; 3; 5; 7.5; 10; 15; 20; 30; 50; 75; 100; 150; 200; 300; 500; 750; 1,000 kHz
  • BIA measuring electricity: 100 µA

Functions and Properties

  • TARE
  • Pre-TARE
  • HOLD
  • Auto-HOLD
  • RESET
  • Step-off
  • Weighing range switch-over
  • lbs/kg switch-over
  • lbs/kg/sts switch-over
  • cm/inch switch-over
  • Calibration / automatic calibration
  • BMI
  • User-defined zero setting
  • SEND/Auto-SEND
  • Ethernet
  • 8 point measurement
  • Segmental measurement
  • Multi-frequent measurement
  • Patient data input
  • Acoustic signals can be activated
  • Wireless
  • Backlighting
  • Date and time at printout

Scope of Delivery

  • One licence of seca analytics 115
  • Measuring tape seca 201
  • Power adapter